6
Replace the main fuse:
1. Unplug the mains cable from the output socket.
2. Open the fuse holder and replace the fuse with one of the same type. The fuse rating is listed on
the rating label.
SPECIFICATIONS:
Multi-color
12 Rotating gobo patterns
Gobo shake function
DMX-512/4 channels
Standalone auto mode
Sound activated
Master/slave function
Menu display
Fan-cooled
Adjustable mounting bracket
Lamp: ELC 24V/250W GX5.3 (included)
Power supply: 230 V AC, 50/60 Hz
Dimensions (WxHxD): 365x195x365mm
Weight: 4.3kg
TROUBLESHOOTING:
Problem Probable cause Solution
One or more xtures are
completely dead.
No power to the xture.
Make sure that cables are plugged
in and power is switched on.
Main fuse blown. Replace fuse.
Fixture is working correctly
but no light output.
Broken or worn out lamp. Install new lamp.
Fixtures reset correctly
but all respond erratically
or not at all to controller.
Controller not connected. Connect controller.
XLR pin-out of controller does
not match pin-out of rst xture
on link (polarity is reversed).
Install a phase-reversing cable
between controller and rst xture
on link.
Fixtures reset correctly but
some respond erratically
or not at all to controller.
Bad data link connection.
Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables.
Data link not terminated with
120 Ohm termination plug.
Insert termination plug in output of
last xture on link.
Incorrect xture addressing. Check DMX addresses.
One of the xtures is
transmitting as a master.
Check all xture settings.
One of the xtures is defective.
Bypass one xture at a time (unplug
both DMX connectors and connect
them directly together) until normal
operation is regained. Defective
xture has to be serviced by a
technician.